T8 Tubes & IP65 Fittings
IP65 vapour-proof fittings (4 ft and 5 ft, single and double) with premium T8 tubes at 145 lm/W and a 5-year warranty. Optional backup (100% for 1 hour, single tube).
Food plants wash their lighting with hoses and detergent, run it for long hours and need it to be easy to inspect and clean. This guide covers how to choose wash-down LED lighting for processing halls, packing rooms, cold stores and yards.
Food and beverage lighting is judged on how it copes with water, cleaning, humidity and long hours. We don't claim food-safety or hygiene certification for any range. These are the engineering factors to specify.
Processing areas are cleaned with hoses and detergent. IP65 protects against water jets and IP66 against powerful water jets, and both are dust-tight. Tubes on their own are IP40, so in wet areas fit them in IP65 vapour-proof fittings. If your cleaning uses very high-pressure or hot spray, tell us and we will confirm the fitting.
Detergents, steam and salt air attack cheap clips and housings. Our IP65 tube fittings use stainless-steel SS304 clips and an ABS base with a UV-stabilised polycarbonate lens. Ask us about your cleaning chemicals if they are unusually aggressive.
Broken glass over open food is a serious contamination event. Polycarbonate lenses and diffusers (as on our IP65 fittings and linear high bays) are the usual approach in these areas, and your own food-safety standard sets the requirement. Confirm the exact model for your audit.
Operators and inspectors judge colour and defects by eye. A neutral to cool white (around 4000 K to 5000 K) is common in processing and inspection, with the lux level raised in inspection zones.
Moving between chilled and ambient rooms creates condensation. Sealed IP65 fittings keep moisture out of the electrics. Tell us the room temperature so we can check it against the model.
Many plants run two or three shifts and are audited regularly. Fewer failures mean fewer maintenance interventions in hygiene zones, and datasheets and warranty documents make audit files simpler.
Plants often have hundreds of sound bulkhead housings. Our retrofit kits replace the light engine and driver inside compatible housings, which avoids a full rewire and cuts waste. Retrofit kits are IP65 once installed in a sound, correctly sealed housing.
Ultranova ranges that suit processing, packing, cold storage and external yards. Every model, specification and datasheet is on the product pages.
IP65 vapour-proof fittings (4 ft and 5 ft, single and double) with premium T8 tubes at 145 lm/W and a 5-year warranty. Optional backup (100% for 1 hour, single tube).
50–200 W, IP65, high-impact polycarbonate diffusers and a 5-year warranty. Four optics to suit lines and aisles.
70–200 W, IP66 with a 7-year warranty, for halls above about 4 m.
Retrofit kits keep sound housings; the Titan 60 W is IP66 and IK10. Emergency backup option (20% output for 3 hours).
Local floods 50–200 W (IP65) for yards and loading, heavy floods for large areas.
Send us these and we can recommend and quote accurately:
From our sales records: We have supplied LED high bays to a bakery-ingredients manufacturer and a tea producer, flood lights to a dairy producer, and bulkhead retrofits and refurbishment to a poultry producer (client names withheld, taken from our sales records). This is a supply history, not a case study, and no results are claimed.
Typical maintained illuminance levels for food and beverage areas are below. They are general guidance only. Your food-safety standard, customer specification and SANS 10114-1 set the level you must meet.
| Area or task | Typical range | Notes |
|---|---|---|
| Food preparation and processing | 300–500 lx | Even light, low glare |
| Inspection and quality control | 500–750 lx | Colour and defect checks |
| Packing and labelling | 300–500 lx | Label reading |
| Wash-down and cleaning areas | 200–300 lx | IP65 or IP66 fittings |
| Cold stores and dry stores | 100–200 lx | Check temperature rating |
| Loading bays and dispatch | 150–200 lx | Floods or high bays |
| Plant rooms and utilities | 100–200 lx | Vapour-proof fittings |
Typical ranges, based on general guidance such as SANS 10114-1 and common international practice. They are not a certification claim. A lighting layout confirms the level for your areas.
Low, wet rooms suit tube fittings. Taller halls move to linear or UFO high bays. The linear figures are guides derived from lumen output.
| Mounting height / area | Starting point | Typical use |
|---|---|---|
| Up to 3.5 m | IP65 fitting with 2 × 18 W or 23 W T8 | Wash-down rooms, packing, stores |
| 3.5–5 m | Linear 50–100 W or UFO GEN2 70 W | Processing halls |
| 5–8 m | UFO GEN2 70–100 W or Linear 100–150 W | Larger halls |
| 8–10 m | UFO GEN2 150 W | Tall processing and storage |
| 10–14 m | UFO GEN2 200 W | High stores and tank halls |
| Yards and docks | Local flood 100–200 W | Aim to the apron |
| Above 14 m | Layout needed | Optics and spacing |
Indicative only. Optic, spacing and the lux target determine the final fitting and quantity.
A hypothetical processing plant with 150 existing twin 36 W fluorescent fittings (about 80 W each including ballast), replaced with IP65 double fittings carrying two 18 W T8 LED tubes (36 W), and running 20 hours a day, 360 days a year.
| Fittings | 150 |
| Existing | 2 × 36 W fluorescent (incl. ballast): 80 W each |
| LED | 2 × 18 W LED in IP65 fitting: 36 W each |
| Operation | 20 h/day × 360 days = 7 200 h/year |
| Tariff (example) | R2.50/kWh |
| Emission factor (assumed) | 0.95 kg CO₂/kWh |
Calculation: fittings × (existing W − LED W) × hours × days ÷ 1 000. It is the same method as our calculator.
Estimate only, for a hypothetical site. Not a customer result. The existing fitting wattage here is an assumption. Measure yours, and use your own hours and tariff. It excludes demand charges, maintenance savings and installation cost, and is not a quotation or a guarantee.
Run it with your numbersStraight answers on specifying LED lighting for food and beverage processing.
Ask us your questionIP65 or IP66. IP65 resists water jets and IP66 resists powerful water jets, and both are dust-tight. T8 tubes alone are IP40, so use them in IP65 vapour-proof fittings in wet areas. If your cleaning uses very high-pressure or hot spray, tell us so we can confirm the fitting.
Our IP65 tube fittings and linear high bays use polycarbonate lenses and diffusers rather than glass. Your own food-safety standard defines what is acceptable, so confirm the model against it. We don't claim food-safety certification.
Often, yes. Our 46 W and 54 W retrofit kits fit compatible industrial bulkhead housings and are IP65 once installed in a sound, sealed housing. We confirm compatibility from a photo or sample.
Sealed IP65 fittings keep condensation out of the electrics. Tell us the room temperature so we can check it against the model before you order, because we confirm temperature suitability per product.
Backup gear is available on selected bulkheads (20% output for 3 hours) and on 18 W and 23 W T8 tubes in IP65 fittings (100% output for 1 hour on a single tube).
Datasheets and warranty terms for each range, IES files on request, and a written quote that states the model, quantity and warranty. We don't claim food-safety certification, so match our documents to your audit requirements.
Send the area, mounting height, what is installed now and the hours it runs. We will recommend the fittings, run a lighting layout if you need one, and send a written quote with datasheets.