Warehousing & Logistics lighting guide

LED high bay lighting for warehouses and distribution centres

A warehouse needs light on the pick face and down the aisle, not just a bright ceiling. This guide covers how to light racking, open floors, loading docks and yards with industrial LED, and how to size it.

50–200 WLinear aisle high bays
30°–120°Optics for aisles and open floors
IP65 / IP66Linear / UFO ingress rating
5–7 yearsWarranty, by range

The short answer

  • Open floors and bulk storage: UFO High Bay GEN2, with the wattage chosen by mounting height (70 W at 4–6 m up to 200 W at 10–14 m).
  • Racking aisles: Linear High Bay (50–200 W) with 30°, 60° or 90° optics, so light lands in the aisle.
  • Loading docks, yards and truck parks: Flood & High-Mast, with Apex area lights for roads and parking.
  • Replacing 400 W metal halide: confirm with a lighting layout and IES file before ordering.
The environment

Lighting challenges in warehouses and distribution centres

Warehouse lighting fails in predictable ways: dark aisles under a bright roof, glare for forklift drivers and costly lamp changes at height. These are the factors to design around.

01

Racking shadows and dark aisles

High racking blocks light from the ceiling. A round high bay with a wide beam lights the top of the racking and leaves the aisle floor and pick face dim. Linear high bays with narrow optics put the light down the aisle, which is why aisle layouts usually specify linear fittings along each aisle.

02

Vertical illuminance at the pick face

Pickers read labels on the rack face, not the floor. Floor lux alone does not tell you whether labels are readable. Ask for a lighting layout that checks light on the rack face as well as the floor.

03

Mounting height and lamp changes

Many distribution centres have 8 to 12 m clear height. Changing a lamp means an elevated work platform, a permit and a pause in operations. A long rated life (100 000 hours on the UFO GEN2) cuts how often that is needed.

04

Long operating hours

Two or three shift operations and 24/7 dispatch run lights for 5 000 to 8 760 hours a year, so energy cost dominates the lifetime cost of the lighting. This is where LED replacing metal halide pays back, and why we show the energy estimate below.

05

Forklift traffic and glare

Drivers look up at racking and across wide aisles. A 120° optic on a low mounting height can glare. Match the optic to height and layout, and keep lit zones consistent so drivers' eyes do not keep readjusting.

06

Docks, yards and weather

Loading docks and truck yards mix indoor and outdoor lighting needs, with rain, dust and night-time reversing. Floods with IP65 or better, aimed to cover the dock apron and trailer interior, serve better than recycled indoor fittings.

07

Dust in bulk storage

Grain, cement, fertiliser and similar stock produce dust that settles on fittings. IP65 keeps it out, and IP66 on the UFO GEN2 adds protection when floors are hosed down or washed.

Recommended products

Ultranova lighting for warehouses and distribution centres

Combine the ranges below by zone. Most distribution centres use UFO high bays on open floors, linear fittings in aisles and floods outside.

What to specify

Send us these and we can recommend and quote accurately:

  • Clear height to the underside of the roof and to the lowest obstruction (sprinklers, ducts, cranes).
  • Racking layout: aisle width, rack height and direction, so the optic and fitting line can be chosen.
  • Operating pattern: shifts, hours per day and days per year, which drives the energy estimate.
  • Existing fittings and wattage, and whether you want a phased replacement.
  • Docks and yards: apron size, number of bays and pole positions.
  • Emergency and escape routes, if backup gear is required.
Typical lux levels

Typical lux levels for warehouses and distribution centres

Typical maintained illuminance levels for warehouse areas are below. They are general guidance only, and your client, insurer or standards (such as SANS 10114-1) set the level you must meet.

Area or taskTypical rangeNotes
Circulation and bulk storage100–150 lxFloor level, open floor
Racking aisles (floor and rack face)150–300 lxCheck the vertical level on the rack face
Picking and sorting300–500 lxLabel reading and small items
Packing and dispatch300–500 lxPacking benches and scanning
Loading and unloading bays150–200 lxTrailer interior needs light too
Offices and control300–500 lxAvoid glare on screens
Yards and truck parks10–30 lxHigher at the dock apron

Typical ranges, based on general guidance such as SANS 10114-1 and common international practice. They are not a certification claim. A lighting layout confirms the level for your racking and operation.

Sizing

Mounting height and wattage guide

Wattage follows mounting height. Use the UFO bands for open floors. For aisles, the optic matters as much as the wattage.

Mounting height / areaStarting pointTypical use
4–6 mUFO GEN2 70 WLow-bay storage, mezzanines
6–8 mUFO GEN2 100 WGeneral storage and packing
8–10 mUFO GEN2 150 WTypical distribution-centre height
10–14 mUFO GEN2 200 WHigh-bay storage and large cross-dock
Aisles to about 8 mLinear 100–150 W, 30°–60°Indicative, set by aisle width and rack height
Aisles above 8 mLinear 150–200 W, 30°–60°Indicative, confirm with a layout
Dock walls and yardsLocal flood 100–200 WAim to the apron

Indicative only. The aisle figures are guides worked from the lumen output of the models, not a layout.

Energy estimate

Energy savings example for warehouses and distribution centres

A hypothetical distribution centre with 60 existing 250 W metal halide fittings (about 290 W each including gear) at 6–8 m, replaced one-for-one with 100 W UFO GEN2 high bays, running 16 hours a day, 300 days a year.

Fittings60
Existing250 W metal halide (incl. gear): 290 W each
LED100 W UFO GEN2: 100 W each
Operation16 h/day × 300 days = 4 800 h/year
Tariff (example)R2.50/kWh
Emission factor (assumed)0.95 kg CO₂/kWh

Calculation: fittings × (existing W − LED W) × hours × days ÷ 1 000. It is the same method as our calculator.

Estimated saving per year (illustrative)
R 136 800
Energy saved54 720 kWh
Reduction66%
Connected load reduction11.4 kW
CO₂ avoided52.0 t

Estimate only, for a hypothetical site. Not a customer result. A real project should be checked with a lighting layout for lux, uniformity and rack-face lighting, and your tariff and hours will differ. It excludes demand charges, maintenance savings and installation cost, and is not a quotation or a guarantee.

Run it with your numbers
FAQ

Warehousing & Logistics lighting questions

Straight answers on specifying LED lighting for warehouses and distribution centres.

Ask us your question
Should I use round UFO high bays or linear high bays in a warehouse?

Use UFO high bays over open floors, cross-dock and bulk storage. Use linear high bays along racking aisles, where narrow 30° or 60° optics put the light down the aisle instead of onto the top of the racking. Many sites use both.

What wattage do I need for a 9 m warehouse?

As a first pass, 150 W UFO GEN2 high bays cover 8–10 m. Racking, wall and ceiling reflectance, and the lux you need change the answer, so we confirm with a lighting layout.

Can I replace 400 W metal halide fittings one for one?

Often a 150 W or 200 W UFO GEN2 is the starting point, depending on height and the lux you need. We confirm with an IES-based layout so you are not guessing, because LED distribution differs from metal halide.

What is vertical illuminance and why does it matter in racking?

It is the light falling on the vertical rack face, where labels and products are. A warehouse can have good floor lux and poor light at the pick face. Ask for a layout that checks both.

What lighting suits loading docks and truck yards?

IP65 or better floods aimed across the apron and into the trailer, mounted on the dock wall or a pole. The local flood range (50–200 W) suits most docks, and the heavy range (400–2 000 W) suits large truck parks.

Do you offer emergency lighting for warehouses?

Backup gear is available on selected bulkheads (20% output for 3 hours) and on T8 tubes in IP65 fittings (100% output for 1 hour on a single tube). Tell us which routes and areas need it.

Get a quote for your warehousing & logistics site.