Mon–Fri 07:30–16:00 · Pretoria, Gautengsales@ultranova.co.za068 900 8948
ULTRANOVA Industrial SolutionsEst. 2016
Sports Fields & Stadiums lighting guide

LED sports field and stadium flood lighting

Sports lighting is about even light on the playing surface, controlled glare and spill, and fittings that survive on a mast. This guide covers how to choose and size LED floods for fields, courts, stadium areas and surrounding car parks.

50–2 000 WFlood lights, local to heavy
30°–120°Four beam optics
140 lm/WHeavy-range light engine
5 yearsFlood warranty

The short answer

  • Large fields and stadium areas: heavy floods at 1 000 W and 2 000 W, with 30°–120° optics chosen from the throw distance.
  • Courts, school fields and small clubs: local floods (100–200 W) and 400 W heavy floods on poles.
  • Car parks, access roads and walkways: Apex area lights (30–160 W, IP66, IK09).
  • Layout first: pole positions, heights and aiming decide the result, so we recommend an IES-based layout before ordering.
The environment

Lighting challenges in sports fields and stadiums

A bad sports installation shows quickly: dark patches, glare in players' eyes, light spilling into neighbours' houses. These are the factors to get right.

01

Uniformity across the playing surface

Players and cameras notice dark corners and hot spots. Uniformity depends on pole positions, mounting height and aiming as much as on wattage, so the layout comes first and the fitting second.

02

Glare and spill light

Glare dazzles players and spectators, and spill annoys neighbours and can breach local conditions. Narrow optics (30° and 60°) aimed down, and well-placed poles, reduce both. Our floods come in 30°, 60°, 90° and 120°.

03

High output at distance

Large fields need big lumen packages thrown over distance. The heavy flood range runs 400 W, 1 000 W and 2 000 W on a 140 lm/W light engine. Lumen packages are confirmed per optic on your quote.

04

Masts, access and maintenance

Poles of 15 m and higher need a crane or a lowering system for any service work. A 50 000-hour rated life reduces how often that is needed. A school field used a few evenings a week could run for many years before the rating is reached.

05

Lightning and surge exposure

Tall masts in open ground attract lightning and surges. Ask us about surge protection on the range you choose, because it differs by product. Our Apex area lights carry 6 kV surge protection (10 kV and 20 kV optional).

06

Instant on, no warm-up

Metal halide floods need warm-up time and a long restrike delay after a power dip. LED floods start at full output, which suits training sessions and community use where lights go on and off.

07

Level of play

A recreational field, a club ground and a televised stadium need very different lux levels and uniformity. Tell us the level, and the federation or broadcaster requirements if there are any, because those requirements are stricter than general guidance.

Recommended products

Ultranova lighting for sports fields and stadiums

Ultranova ranges for sports and outdoor areas. Full models and datasheets are on each product page.

What to specify

Send us these and we can recommend and quote accurately:

  • Sport, level of play and any federation or broadcaster requirements.
  • Field and court dimensions, with a site plan showing where poles can go.
  • Pole heights available, or whether new poles are needed.
  • Neighbours, roads and any local limits on spill light.
  • Hours of use: training only, competition, or both.
  • Supply and surge protection, especially on exposed masts.

From our sales records: We have supplied LED flood lights to an equipment-hire company for its hire fleet and to a dairy producer for yards and loading (client names withheld, taken from our sales records). This is a supply history, not a case study, and no results are claimed.

Typical lux levels

Typical lux levels for sports fields and stadiums

Typical illuminance levels for sports are below. They are general guidance only. Your sport's federation, the level of play, and any broadcast requirements set the real figure, and those are stricter than this table.

Area or taskTypical rangeNotes
Recreational and school training fields50–150 lxEvening training
Club competition (football, rugby, hockey)200–300 lxClub-level matches
Tennis, netball and basketball courts (outdoor)200–500 lxSmaller area, higher level
Higher-level competition500 lx and aboveFederation and broadcast rules apply
Athletics tracks (training)100–200 lxUniform along the track
Spectator areas, walkways and entrances10–50 lxSafe movement
Car parks and access roads5–20 lxApex area lights on poles

Typical ranges, based on general guidance and common international sports lighting practice. They are not a certification claim. The federation or competition requirements for your sport apply, and a lighting layout confirms the level.

Sizing

Mounting height and wattage guide

Pole height and distance drive the wattage. These bands are indicative starting points and a layout confirms pole count and aiming.

Mounting height / areaStarting pointTypical use
Walls or poles to about 8 mLocal flood 100–200 WCourts, small fields, yards
Poles 10–15 mHeavy flood 400 WSchool and club fields
Poles 15–25 mHeavy flood 1 000 WClub and larger fields
Masts above 25 mHeavy flood 1 000–2 000 WStadium-scale areas
Car park and road poles 5–15 mApex 30–160 WSpigot mount, IP66
Indoor halls to 14 mUFO GEN2 70–200 WSports halls
Optics30°–60° long throw, 90°–120° short throwChoose from distance to the field

Indicative only. Pole position, aiming and the level of play decide the final fitting and quantity, so a layout is needed.

Energy estimate

Energy savings example for sports fields and stadiums

A hypothetical club field with 12 existing 1 500 W metal halide floods (about 1 650 W each including gear), replaced like-for-like with 1 000 W LED floods, and running 4 hours an evening, 300 days a year.

Fittings12
Existing1 500 W metal halide (incl. gear): 1650 W each
LED1 000 W LED flood: 1000 W each
Operation4 h/day × 300 days = 1 200 h/year
Tariff (example)R2.50/kWh
Emission factor (assumed)0.95 kg CO₂/kWh

Calculation: fittings × (existing W − LED W) × hours × days ÷ 1 000. It is the same method as our calculator.

Estimated saving per year (illustrative)
R 23 400
Energy saved9 360 kWh
Reduction39%
Connected load reduction7.8 kW
CO₂ avoided8.9 t

Estimate only, for a hypothetical site. Not a customer result. Sports lights run few hours, so energy savings are modest. The other benefits are instant start and less maintenance. A layout confirms whether the replacement is truly like-for-like. It excludes demand charges, maintenance savings and installation cost, and is not a quotation or a guarantee.

Run it with your numbers
FAQ

Sports Fields & Stadiums lighting questions

Straight answers on specifying LED lighting for sports fields and stadiums.

Ask us your question
What wattage flood do I need for a sports field?

It depends on the level of play, pole height and distance to the far side. As a starting point, 400 W on 10–15 m poles suits school and club fields, with 1 000 W and 2 000 W for larger fields and masts. A layout confirms pole count and aiming.

What beam angle should I choose?

Narrow optics (30° and 60°) throw further and control glare for long distances. Wider optics (90° and 120°) suit short throws and wide spread. We choose from your pole positions and the field geometry.

How do you control glare and spill light?

Mount high, aim down, choose the narrowest optic that covers the area, and place poles carefully. A lighting layout shows spill and glare before installation. Tell us about neighbours and any local conditions.

Is LED better than metal halide for sports lighting?

LED floods start at full output and need no restrike delay, and they last longer between services. Because sports lights run few hours a year, energy savings are smaller than for 24/7 plants, so the maintenance and start-up benefits count for more.

Do you supply lighting for broadcast or international-level play?

Competition and broadcast lighting is governed by federation and broadcaster requirements for lux, uniformity and flicker. Tell us the requirement and we will advise whether our range is suitable before you order. We don't make that claim in general.

Can you light the car park and access roads too?

Yes. Apex area lights run 30 W to 160 W, with IP66 and IK09 protection, 140–145 lm/W and a spigot mount for 5–15 m poles.

Get a quote for your sports fields & stadiums site.

Send the area, mounting height, what is installed now and the hours it runs. We will recommend the fittings, run a lighting layout if you need one, and send a written quote with datasheets.

Get a quoteWhatsApp