Mon–Fri 07:30–16:00 · Pretoria, Gautengsales@ultranova.co.za068 900 8948
ULTRANOVA Industrial SolutionsEst. 2016
Mining lighting guide

LED high bay and flood lighting for mining in South Africa

Surface plants, crusher and screening buildings, workshops, conveyor galleries and stockyards all punish light fittings. Here is how to choose and size industrial LED lighting for mining sites, and which Ultranova ranges suit each area.

IP66Dust-tight, jet-proof high bays
100 000 hRated life, UFO GEN2
90–305 VUFO input window
7 yearsUFO GEN2 warranty

The short answer

  • Plant halls and workshops: UFO High Bay GEN2 (70–200 W, IP66, 90–305 V AC input, 7-year warranty).
  • Stockpiles, loading and yards: Flood & High-Mast range, from 50 W up to 2 000 W.
  • Conveyor galleries, walkways and substations: bulkhead retrofit kits, or the IK10 Titan where impact is a risk.
  • Classified or gassy areas: zone lighting only, with the certificate and limits confirmed in writing per project.
The environment

Lighting challenges in mining

Mining lighting is not office lighting scaled up. These are the conditions that decide whether a fitting lasts, and what to ask about each one.

01

Dust and fines

Crushing, screening and conveyor transfer points fill the air with fine material that settles on everything. A fitting that is only splash-proof lets it in. IP66 means dust-tight (the first 6) and protected against powerful water jets (the second 6), so a plant can be hosed down without opening the fitting. Smooth aluminium bodies are also easier to clean than fins packed with caked dust.

02

24/7 duty

Many plants run around the clock, which is 8 760 hours a year. At that duty the UFO GEN2's 100 000-hour rated life works out to roughly 11 years of continuous operation. That is a rating, not a promise: the written warranty on the UFO GEN2 is 7 years, and that is the figure on your quote.

03

Unstable supply

Remote sites run on long cable runs, generators and weak feeders, and voltage swings are normal. The UFO GEN2 accepts 90–305 V AC with a power factor above 0.95, so it tolerates sags and surges that cheaper 220–240 V drivers do not. Ask us about surge protection on the range you choose, because it differs by product.

04

Mounting height and access

Crusher houses and screening buildings are often 10 to 20 m to the underside of the roof, and getting a lift or crane in means a planned shutdown. Long-life fittings reduce how often that happens. Our height guidance for the UFO runs up to 14 m, and above that we recommend a lighting layout with narrower optics rather than guessing.

05

Vibration and impact

Crushers, mills and screens shake buildings. Rigid brackets matter as much as the fitting. We do not claim vibration certification for the standard ranges, so tell us about severe vibration and we will advise. Where impact is the risk (walkways, low galleries, vehicle areas) the Titan bulkhead is rated IK10.

06

Classified and underground areas

Gassy or classified areas, and underground workings, are governed by mine-specific rules and equipment approvals. Our standard industrial ranges are not offered for those areas. Our zone range is documented per project: the zone rating and limits are confirmed in writing with your quote, before anything is installed, and the certification pack supplied with your order.

07

Glare and night work

Stockyards and loading areas are worked at night by drivers and spotters. Floods with 30° or 60° optics, aimed down and away from the operator's eye line, reduce glare and spill. The Flood & High-Mast range comes in 30°, 60°, 90° and 120°.

Recommended products

Ultranova lighting for mining

These are the Ultranova ranges that fit each mining area. Every model, specification and datasheet is on its product page.

What to specify

Send us these and we can recommend and quote accurately:

  • IP rating for the area: IP66 for dusty or washed-down areas, IP65 minimum elsewhere.
  • Supply: nominal voltage, expected swings, and whether the feed is mains, generator or both.
  • Mounting height to the fitting (not to the floor), and what can obstruct the beam (cranes, pipework, platforms).
  • Colour temperature: 4000 K is a common choice for plants, with 5000 K where crisp visibility matters.
  • Emergency requirements: backup gear is available on selected bulkheads (20% output for 3 hours).
  • Documents required by your site: datasheets, IES files, warranty letter, and, for any zone product, the certification pack (supplied with your order).
Typical lux levels

Typical lux levels for mining

Typical maintained illuminance levels for surface mining areas are below. They are general guidance only. Your mine's standards, the Mine Health and Safety requirements that apply to you and your client's specification come first.

Area or taskTypical rangeNotes
Walkways, stairs, conveyor galleries50–100 lxHigher at stairs and trip hazards
Crusher, screening and mill buildings100–200 lxDusty areas lose output between cleans
Workshops and maintenance bays300–500 lxDetail work may need local task lighting
Control rooms and offices300–500 lxScreen work: avoid glare on displays
Loading and tipping areas30–100 lxDirection of approach affects glare
Stockyards and open yards10–30 lxWider area, aim floods carefully
Plant roads and parking5–20 lxApex area lights on poles

Typical ranges, based on general industrial guidance such as SANS 10114-1 and common international practice. They are not a certification claim and do not replace the standard or your mine's requirements. Underground lighting is outside this table.

Sizing

Mounting height and wattage guide

Use the UFO GEN2 height bands below as a first pass for covered areas, then confirm with a layout. Outdoor figures are indicative rules of thumb, because pole spacing, optics and the lux you need change them.

Mounting height / areaStarting pointTypical use
4–6 mUFO GEN2 70 WLow workshops, stores, MCC rooms
6–8 mUFO GEN2 100 WWorkshops, small plant buildings
8–10 mUFO GEN2 150 WPlant halls, mill buildings
10–14 mUFO GEN2 200 WCrusher houses, large halls
Above 14 mLayout neededNarrow optics, more fittings, or side-mounted floods
Yard, wall or short pole (to about 8 m)Local flood 100–200 WLoading bays, walls, laydown
Masts (about 10 m and higher)Heavy flood 400–1 000 WStockyards, tipping, large open areas

Indicative only. Optic angle, spacing and lux target determine the final fitting and quantity.

Energy estimate

Energy savings example for mining

A hypothetical processing-plant hall with 40 existing 400 W metal halide fittings (about 455 W each including gear), replaced one-for-one with 150 W UFO GEN2 high bays and running 24 hours a day, 365 days a year.

Fittings40
Existing400 W metal halide (incl. gear): 455 W each
LED150 W UFO GEN2: 150 W each
Operation24 h/day × 365 days = 8 760 h/year
Tariff (example)R2.50/kWh
Emission factor (assumed)0.95 kg CO₂/kWh

Calculation: fittings × (existing W − LED W) × hours × days ÷ 1 000. It is the same method as our calculator.

Estimated saving per year (illustrative)
R 267 180
Energy saved106 872 kWh
Reduction67%
Connected load reduction12.2 kW
CO₂ avoided101.5 t

Estimate only, for a hypothetical site. Not a customer result. Real savings depend on your actual wattages, hours and tariff. A like-for-like replacement should be checked with a lighting layout, because LED output and distribution differ from metal halide. It excludes demand charges, maintenance savings and installation cost, and is not a quotation or a guarantee.

Run it with your numbers
FAQ

Mining lighting questions

Straight answers on specifying LED lighting for mining.

Ask us your question
Do you supply LED lighting for underground mines?

Our standard industrial ranges are for surface plants, workshops and yards. Underground workings, and gassy or classified areas, have their own equipment approval rules. We don't offer the standard ranges for those areas. For a classified-area project, our zone range is documented per project, and the certificate, zone rating and limits are confirmed in writing before you order.

Is IP66 enough for a dusty crusher or screening plant?

IP66 means the fitting is dust-tight and protected against powerful water jets, which is the right starting point for dust and hose-down cleaning. How often you clean the fittings still matters, because heavy dust build-up on a housing reduces output over time. The UFO GEN2 is IP66.

How long will a high bay last on a 24/7 plant?

The UFO GEN2 has a rated life of 100 000 hours, roughly 11 years at 24 hours a day. The written warranty is 7 years, so the warranty is the figure to plan around. Heat, supply quality and cleaning affect real-world life.

Can LED fittings cope with generator and weak-feeder supply?

The UFO GEN2 accepts 90–305 V AC and has a power factor above 0.95, which gives it far more tolerance than a narrow-window driver. Tell us the supply conditions and we will advise on surge protection options for the range you choose.

What do I need to send you for a mining quote?

The area type (plant, workshop, yard), mounting height, what is installed now and its wattage, hours of use, supply voltage and any documents your site requires. Photos of the existing fittings help for retrofit and bulkhead work.

Which heavy flood do I need for a stockpile or yard?

It depends on pole height, distance and the lux you need. Heavy floods come in 400 W, 1 000 W and 2 000 W with 30° to 120° optics. We confirm the model and quantity with a layout, and the lumen package is confirmed per optic on your quote.

Get a quote for your mining site.

Send the area, mounting height, what is installed now and the hours it runs. We will recommend the fittings, run a lighting layout if you need one, and send a written quote with datasheets.

Get a quoteWhatsApp